XYCOM XVME-500/1 Analog Input Module

Brand/Manufacturer: XYCOM 

Order Number:  XVME-500/1 

Country of Origin: USA

Condition: Original Brand

Lead Time: Available in stock

Payment Term: 100% TT In Advance


Send Inquiry
Power Duke Automation Equipment Co., Ltd.
Sales Manager: Anne
WeChat: +86 19336875129
Email: Anne@yuanmiaoautomation.com
We can offer you the best price!
Image 2
Image 2

Products Description

XYCOM XVME-500/1 Analog Input Module Full Technical Datasheet

1. Brand & Basic Info

  • Brand: XYCOM (Acromag Xembedded, Schneider industrial VME platform)
  • Model: XVME-500/1, OEM part number 70500-006
  • Form Factor: 3U single-height VMEbus slave analog input board
  • Lifecycle: Fully discontinued OEM production; stock includes fully tested refurbished units & limited new surplus
  • Host Compatibility: Works with XVME-601 (68K), XVME-674 (486), XVME-655 (Pentium) VME master CPU controllers

2. Channel Configuration

  • Standard base channels: 16 single-ended (SE) / 8 differential (DIFF)XYCOM
  • Expandable to 32 SE /16 DIFF via optional XVME-910 channel expansion kit
  • A/D Converter: 12-bit successive approximation ADC
  • Precision specs:
    • Linearity: ±0.5 LSB (monotonic guaranteed)XYCOM
    • System accuracy: ±0.01% FSR (gain ×1); ±0.1% FSR (max gain ×1000)
    • Input impedance: ≥10 MΩ ultra-high impedance (minimal sensor loading)XYCOM
    • Max safe continuous input voltage: 14 VDCXYCOM

3. Gain & Voltage Ranges (Core Difference from /2 /3 /4)

XVME-500/1 Fixed Resistor Gain (hardware resistor selected, no software programmable gain)XYCOM

Fixed gain tiers: ×1, ×10, ×100, ×1000 (set by soldered onboard resistors)

Jumper-selectable full-scale voltage ranges

  • Unipolar: 0–10 V
  • Bipolar: ±5 V, ±10 VXYCOM
  • CMRR (Common Mode Rejection Ratio): ≥60 dB for heavy EMI factory environmentsXYCOM

4. Sampling & Conversion Performance

  • Max total scan throughput: 20 kHz overall conversion speedXYCOM
  • Supported trigger modes:
    1. Immediate single-channel conversion
    2. Auto sequential multi-channel scan
    3. Random address channel access
    4. External hardware trigger sync (encoder/machine motion lock)
  • End-of-conversion (EOC) flag for hardware interrupt triggering

5. VMEbus Interface (IEEE 1014 Standard)

  • Bus role: VME slave only (A16/A24 address, D08/D16 data width)
  • Interrupt: Jumper configurable IRQ0–IRQ7 VME interrupt levels, ROAK interrupt acknowledge chain
  • Onboard registers: Control register, channel select register, status register, 16-bit conversion data register
  • Rear: Standard 96-pin VME P1 backplane connector; Front panel high-density terminal block for field sensor wiring