Products Description
XYCOM XVME-500/4 Analog Input Module
1. Brand & Model Basic Info
- Brand: XYCOM (Schneider Electric Xembedded division)
- Full Model: XVME-500/4, factory part number 70500-011
- Form Factor: 3U single-height VMEbus slave analog input board
Production Status: Fully discontinued OEM production; only refurbished tested units & limited new surplus availab
le Host Compatibility: Matches XVME-601, XVME-602 VME master CPU processors for legacy process control racks
2. Channel Configuration (XVME-500/4 Standard)
- Max channels: 32 single-ended (SE) / 16 differential (DIFF) (base 16SE/8DIFF, expandable to full count via XVME-910 expansion kit)
- A/D Resolution: 12-bit successive approximation ADC
- Accuracy: ±0.01% FSR at gain ×1; ±0.1% FSR at high gain; linearity ±0.5 LSB, fully monotonic conversion
3. Voltage Ranges & Gain Setup
Jumper-selectable full-scale input ranges
- Unipolar: 0–10 V
- Bipolar: ±5 V, ±10 V
Onboard programmable gain tiers (XVME-500/4 platform)
Gain options: ×1, ×2, ×5, ×10 / ×4, ×8, ×20, ×40 / ×10, ×20, ×50, ×100 (multi-stage jumper configured)
- Input impedance: 10 MΩ minimum ultra-high impedance (minimal sensor loading)
- Max safe input voltage: 14 V continuous; robust surge protection for field wiring faults
4. Sampling & Conversion Performance
- Max throughput speed: 20 kHz total scan rate
- Supported sampling trigger modes:
- Single-channel immediate conversion
- Sequential auto-scan across channel bank
- Random channel address access
- External hardware trigger capture (for sync with machine motion/encoder pulses)
- Common Mode Rejection Ratio (CMRR): ≥60 dB for industrial EMI heavy environments
5. VMEbus Interface Logic
- Bus standard: IEEE 1014 VMEbus, A16/A24 address, D08/D16 data width (slave only)
- Interrupt: Jumper configurable IRQ0–IRQ7; end-of-conversion (EOC) hardware interrupt flag
- Register map: Control register, channel select register, status register, 16-bit conversion data register
- Rear connector: Standard 96-pin VME P1 bus connector; front panel high-density field terminal block for sensor wiring
6. Electrical Power Specifications
- Powered entirely from VME backplane +5 VDC (±5% tolerance)
- Typical operating current: 1.6 A; maximum peak current: 1.9 A
- Passive fanless cooling design, no forced airflow required
7. Mechanical & Environmental Ratings
- Dimensions: Standard 3U single-height VME form factor
- Net weight: ~0.54 lbs (0.245 kg)
- Operating temperature: 0 °C ~ +50 °C
- Storage temperature: -25 °C ~ +70 °C
- Humidity: 5%–95% non-condensing; resistant to factory dust, mild vibration & electrical noise
- Certifications: CE industrial safety compliant

