I. Product Positioning
The 151X series is a classic spare part system of GE's traditional heavy-duty gas turbines. 151X1215DC29SA01 is an excitation control / excitation power drive signal board, mainly used in the excitation regulation circuits of steam turbine and gas turbine power generation units. It works in conjunction with the exciter machine and AVR automatic voltage regulator to stabilize the output voltage and reactive power of the units.
Core Functions
Excitation current collection and feedback closed-loop regulation
Thermal transistor SCR trigger pulse amplification and drive output
Excitation overcurrent, loss of excitation, and overpressure fault monitoring and interlock trip signal output
High-speed data interaction with the Mark VIe main control backplane, uploading excitation operating condition parameters
Compatible with static excitation and rotating excitation two unit configuration schemes

Electrical Specifications
Working power supply: 125VDC cabinet control power supply + 24VDC auxiliary logic power supply
Trigger output: High-power pulse signal, compatible with high-power thyristor rectifier bridge
Signal isolation: Electrical isolation of strong and weak circuits, resistant to strong electromagnetic interference in power plants
Working temperature: 0℃ ~ 60℃ (standard control cabinet environment)
Insulation withstand voltage: 2000VAC withstand test for input and output to ground

Compatible Unit Models
GE 6FA, 9FA, 7EA, 7HA series heavy-duty gas turbines
Coupled steam turbine combined cycle units
Upgrade of the old Mark VI system and replacement of spare parts for the previous 151X1213PB01/PB02 version

| RS PART NUMBER | DESCRIPTION |
|---|---|
| RS-FS-9001 | FLAME SENSOR (UV) – NA CLASS I DIV 2, ATEX ZONE 2 |
| RS-FS-9004 | FLAME SENSOR (UV) – NA CLASS I DIV 1, ATEX ZONE 1 |
| RS-FS-9006-MFR | FLAME SENSOR (UV) – AERODERIVATIVE (AS9100) |
| RS-FS-9009-03 | FTD 325 – CLASS I DIV 2, ATEX ZONE 2, NO COOLING REQUIRED, MAX TEMP 325°C |
| RS-FS-9010-03 | FTD 325 – CLASS I DIV 1, ATEX ZONE 1, NO COOLING REQUIRED, MAX TEMP 325°C |
| RS-FS-9009-03-25x | FTD 325 ILG – NO COOLING REQUIRED, MAX TEMP 325°C, INCREASED LOW GAIN FOR LOW INTENSITY LIGHT, CLASS I DIV 2, ATEX ZONE 2 |
| RS-FS-9010-03-25x | FTD 325 ILG – NO COOLING REQUIRED, MAX TEMP 325°C, INCREASED LOW GAIN FOR LOW INTENSITY LIGHT, CLASS I DIV 1, ATEX ZONE 1 |
| RS-FS-9100 | FLAME TRACKER LITE FOR INDUSTRIAL APPLICATIONS |
| RS-FS-9100-RELAY | RELAY, 1CH, D5254S |
| RS-FS-9101 | COIL COOLING WATER (GEPS #353B3490G001) |
| RS-FSM-1002-002 | FLAME SENSOR MODULE, MKV |
| SP-566 | COIL COOLING WATER (GEPS #353B3490G001) |
| RS-E2-0266G091 | KIT: (4) RS-FS-9009-03 / (4) RS-E2-0285P004 / MISC. HARDWARE |
| RS-E2-0266G092 | KIT: (4) RS-FS-9009-03 / (4) RS-E2-0285P004 / (1) RS-FSM-1002-002 / HARDWARE |
| RS-E2-0266G093 | KIT: RS-FS-9009-03 MOUNTING HARDWARE |
| RS-E2-0266G094 | KIT: (1) RS-FS-9100 / (1) RS-E2-0285P021 |
| RS-E2-0266G096 | KIT: (1) RS-FS-9100 / (1) RS-E2-0285P021 / (1) CASE / (1) RS STICKER (2) RS-FS-9009-03 / (2) RS-E2-0285P004 / (1) RS-FSM-1002-002 / |
| RS-E2-0266G097 | KIT: (1) RS-E1-0039-003 / HARDWARE |
| RS-E2-0266G098 | KIT: (2) RS-FS-9009-03 / (2) RS-E2-0285P004 / (1) RS-E1-0039-003 / HARDWARE |
| RS-E2-0266G099 | KIT: (8) RS-FS-9009-03 / (8) RS-E2-0285P004 / (2) RS-FSM-1002-002 / HARDWARE |
| RS-E2-0266G100 | KIT: (8) RS-FS-9009-03 / (8) RS-E2-0285P004 / HARDWARE |
| RS-E2-0285P001 | FLAME SENSOR CABLE: 60FT LONG / RIGHT ANGLE CONNECTOR |
| RS-E2-0285P004 | FLAME SENSOR CABLE: 120FT LONG / RIGHT ANGLE CONNECTOR |
| RS-E2-0285P011 | FLAME SENSOR CABLE: 60FT LONG / STRAIGHT CONNECTOR |
| RS-E2-0285P012 | FLAME SENSOR CABLE: 120FT LONG / STRAIGHT CONNECTOR |
| RS-E2-0285P021 | FLAME SENSOR CABLE: 15FT LONG / RIGHT ANGLE CONNECTOR |
Reuter-Stokes Cross Reference Matrix
| RS PART NUMBER | GE PART NUMBER | REPLACES PART NUMBER | DESCRIPTION |
|---|---|---|---|
| RS-FS-9001 | 362A1052P404 | 362A1052P001 362A1052P003 362A1052P004 362A1052P104 362A1052P203 362A1052P243 362A1052P303 362A1052P304 184X0254M029 RRO00148 | FLAME SENSOR (UV) |
| RS-FS-9004 | 362A1052P105 362A1052P406 362A1052P407 | 362A1052P105 362A1052P106 362A1052P107 362A1052P306 362A1052P307 121T9685P0010 184X0254M123 RRO00149 | FLAME SENSOR (UV) |
| RS-FS-9006-MFR | 362A1379P001 L44819P01 | 8TP10LMX J04937 RS-FS-9006 | FLAME SENSOR (UV) – AERODERIVATIVE |
| RS-FS-9009-03 | 124T5712P0001 | RS-FS-9009-01 RRO00345 | FTD 325 |
| RS-FS-9010-03 | 124T5712P0001 | RS-FS-9009-02 RRO00345 | FTD 325 |
| RS-FS-9009-03-25x | 302T1201P0001 | RS-FS-9009-03 | FTD 325 ILG, ZONE 2 |
| RS-FS-9010-03-25x | 302T1201P0002 | RS-FS-9010-03 | FTD 325 ILG, ZONE 1 |
| SP-566 | 353B3490G001 | 362A1053P031 | COIL COOLING WATER |
| RS-E2-0285P001 | 362A1053P031 | 362A1053P036 | CABLE: 60FT / RIGHT ANGLE |
| RS-E2-0285P004 | 362A1053P036 | RS-E2-0285P013 | CABLE: 120FT / RIGHT ANGLE |
| RS-E2-0285P011 | 362A3342P002 | 362A3342P002 | CABLE: 60FT / STRAIGHT |
| RS-E2-0285P012 | RS-E2-0285P013 | 124T5712P0001 | CABLE: 120FT / STRAIGHT |
| RS-E2-0285P021 | RS-E2-0285P011 | RS-E2-0285P011 | CABLE: 15FT / RIGHT ANGLE |