I. Basic Positioning

It belongs to the GE Baker Hughes (formerly GE Power) RXi distributed I/O subsystem. It is a remote substation controller for the Mark VIe heavy-duty gas turbine and steam turbine main control systems. It has independent computing capabilities and shares the scanning load of the main PLC, remotely collecting sensor signals, flame probes, valve positions, temperature and pressure signals from the site.

Core Hardware Configuration

Processor: 16-bit dedicated industrial CPU

Memory: 128KB RAM + 1MB Flash program storage

Bus Compatibility: I/O Bus V16 and above versions, compatible with Compact Logix series upper-level processors (not compatible with MicroLogix1500)


 Communication and IO Capabilities Communication interface

Ethernet: EtherNet/IP and PROFINET dual protocols, used for connecting to the Mark VIe main controller

RS485 serial port: Modbus RTU, for interfacing with third-party instruments and transmitters

Local expansion backplane: Plug-in AI/DI/DO/AO sub-modules

Standard IO capacity (basic complete unit)

4 digital input DI

8 analog input AI (compatible with 4–20mA flame sensors, pressure, temperature)

4 relay output DO (drives solenoid valves, ignition coils, alarm contacts)

Signal adaptation

Perfectly compatible with the 4–20mA signal of the RS-FS-9001 flame probe you previously queried, allowing direct acquisition of flame intensity values and uploading to the engine protection logic.

04240FD11234A.png

Electrical and Environmental Specifications Table

Parameter Item  Technical Value

Power Supply Voltage  24VDC Industrial Standard (±10% tolerance variation)

Channel Isolation  Photoelectric Isolation, Each Channel Independently Insulated

Response Speed  DI/DO: 1–5ms, Configurable Filterable by Software

Operating Temperature  -20℃ ~ +60℃ (Inside Control Cabinet)

Storage Temperature  -40℃ ~ +85℃

Protection Grade  IP20 (DIN Rail / Panel Cabinet Installation)

Explosion-proof Grade  Standard Intrinsic Safety Design, Suitable for Explosion-proof Zone Class I Div.2 of Power Station

Four. Application Scenarios

Main Scene: Remote Signal Acquisition Station for Heavy-duty Gas Turbines Mark VIe Systems such as GE 9FA/6FA/7HA, Combined with RS-FS-9001 Flame Sensor for Flame Outage Protection Interlock

Large-scale Waste Heat Boilers, Combined Cycle Power Plants, Petrochemical Heating Furnace Control Systems

Remote IO Expansion for Distributed Factory Production Lines, Pump Stations, Compressor Groups

Renovation of Old Units to replace Old Models with Remote Controllers (Replacing the Early IS200 Series Substations)


RS PART NUMBERDESCRIPTION
RS-FS-9001FLAME SENSOR (UV) – NA CLASS I DIV 2, ATEX ZONE 2
RS-FS-9004FLAME SENSOR (UV) – NA CLASS I DIV 1, ATEX ZONE 1
RS-FS-9006-MFRFLAME SENSOR (UV) – AERODERIVATIVE (AS9100)
RS-FS-9009-03FTD 325 – CLASS I DIV 2, ATEX ZONE 2, NO COOLING REQUIRED, MAX TEMP 325°C
RS-FS-9010-03FTD 325 – CLASS I DIV 1, ATEX ZONE 1, NO COOLING REQUIRED, MAX TEMP 325°C
RS-FS-9009-03-25xFTD 325 ILG – NO COOLING REQUIRED, MAX TEMP 325°C, INCREASED LOW GAIN FOR LOW INTENSITY LIGHT, CLASS I DIV 2, ATEX ZONE 2
RS-FS-9010-03-25xFTD 325 ILG – NO COOLING REQUIRED, MAX TEMP 325°C, INCREASED LOW GAIN FOR LOW INTENSITY LIGHT, CLASS I DIV 1, ATEX ZONE 1
RS-FS-9100FLAME TRACKER LITE FOR INDUSTRIAL APPLICATIONS
RS-FS-9100-RELAYRELAY, 1CH, D5254S
RS-FS-9101COIL COOLING WATER (GEPS #353B3490G001)
RS-FSM-1002-002FLAME SENSOR MODULE, MKV
SP-566COIL COOLING WATER (GEPS #353B3490G001)
RS-E2-0266G091KIT: (4) RS-FS-9009-03 / (4) RS-E2-0285P004 / MISC. HARDWARE
RS-E2-0266G092KIT: (4) RS-FS-9009-03 / (4) RS-E2-0285P004 / (1) RS-FSM-1002-002 / HARDWARE
RS-E2-0266G093KIT: RS-FS-9009-03 MOUNTING HARDWARE
RS-E2-0266G094KIT: (1) RS-FS-9100 / (1) RS-E2-0285P021
RS-E2-0266G096KIT: (1) RS-FS-9100 / (1) RS-E2-0285P021 / (1) CASE / (1) RS STICKER (2) RS-FS-9009-03 / (2) RS-E2-0285P004 / (1) RS-FSM-1002-002 /
RS-E2-0266G097KIT: (1) RS-E1-0039-003 / HARDWARE
RS-E2-0266G098KIT: (2) RS-FS-9009-03 / (2) RS-E2-0285P004 / (1) RS-E1-0039-003 / HARDWARE
RS-E2-0266G099KIT: (8) RS-FS-9009-03 / (8) RS-E2-0285P004 / (2) RS-FSM-1002-002 / HARDWARE
RS-E2-0266G100KIT: (8) RS-FS-9009-03 / (8) RS-E2-0285P004 / HARDWARE
RS-E2-0285P001FLAME SENSOR CABLE: 60FT LONG / RIGHT ANGLE CONNECTOR
RS-E2-0285P004FLAME SENSOR CABLE: 120FT LONG / RIGHT ANGLE CONNECTOR
RS-E2-0285P011FLAME SENSOR CABLE: 60FT LONG / STRAIGHT CONNECTOR
RS-E2-0285P012FLAME SENSOR CABLE: 120FT LONG / STRAIGHT CONNECTOR
RS-E2-0285P021FLAME SENSOR CABLE: 15FT LONG / RIGHT ANGLE CONNECTOR

Reuter-Stokes Cross Reference Matrix

RS PART NUMBERGE PART NUMBERREPLACES PART NUMBERDESCRIPTION
RS-FS-9001362A1052P404362A1052P001
362A1052P003
362A1052P004
362A1052P104
362A1052P203
362A1052P243
362A1052P303
362A1052P304
184X0254M029
RRO00148
FLAME SENSOR (UV)
RS-FS-9004362A1052P105
362A1052P406
362A1052P407
362A1052P105
362A1052P106
362A1052P107
362A1052P306
362A1052P307
121T9685P0010
184X0254M123
RRO00149
FLAME SENSOR (UV)
RS-FS-9006-MFR362A1379P001
L44819P01
8TP10LMX
J04937
RS-FS-9006
FLAME SENSOR (UV) – AERODERIVATIVE
RS-FS-9009-03124T5712P0001RS-FS-9009-01
RRO00345
FTD 325
RS-FS-9010-03124T5712P0001RS-FS-9009-02
RRO00345
FTD 325
RS-FS-9009-03-25x302T1201P0001RS-FS-9009-03FTD 325 ILG, ZONE 2
RS-FS-9010-03-25x302T1201P0002RS-FS-9010-03FTD 325 ILG, ZONE 1
SP-566353B3490G001362A1053P031COIL COOLING WATER
RS-E2-0285P001362A1053P031362A1053P036CABLE: 60FT / RIGHT ANGLE
RS-E2-0285P004362A1053P036RS-E2-0285P013CABLE: 120FT / RIGHT ANGLE
RS-E2-0285P011362A3342P002362A3342P002CABLE: 60FT / STRAIGHT
RS-E2-0285P012RS-E2-0285P013124T5712P0001CABLE: 120FT / STRAIGHT
RS-E2-0285P021RS-E2-0285P011RS-E2-0285P011CABLE: 15FT / RIGHT ANGLE