Products Description
I. Basic Positioning
It belongs to the GE Baker Hughes (formerly GE Power) RXi distributed I/O subsystem. It is a remote substation controller for the Mark VIe heavy-duty gas turbine and steam turbine main control systems. It has independent computing capabilities and shares the scanning load of the main PLC, remotely collecting sensor signals, flame probes, valve positions, temperature and pressure signals from the site.
Core Hardware Configuration
Processor: 16-bit dedicated industrial CPU
Memory: 128KB RAM + 1MB Flash program storage
Bus Compatibility: I/O Bus V16 and above versions, compatible with Compact Logix series upper-level processors (not compatible with MicroLogix1500)
Communication and IO Capabilities Communication interface
Ethernet: EtherNet/IP and PROFINET dual protocols, used for connecting to the Mark VIe main controller
RS485 serial port: Modbus RTU, for interfacing with third-party instruments and transmitters
Local expansion backplane: Plug-in AI/DI/DO/AO sub-modules
Standard IO capacity (basic complete unit)
4 digital input DI
8 analog input AI (compatible with 4–20mA flame sensors, pressure, temperature)
4 relay output DO (drives solenoid valves, ignition coils, alarm contacts)
Signal adaptation
Perfectly compatible with the 4–20mA signal of the RS-FS-9001 flame probe you previously queried, allowing direct acquisition of flame intensity values and uploading to the engine protection logic.

Electrical and Environmental Specifications Table
Parameter Item Technical Value
Power Supply Voltage 24VDC Industrial Standard (±10% tolerance variation)
Channel Isolation Photoelectric Isolation, Each Channel Independently Insulated
Response Speed DI/DO: 1–5ms, Configurable Filterable by Software
Operating Temperature -20℃ ~ +60℃ (Inside Control Cabinet)
Storage Temperature -40℃ ~ +85℃
Protection Grade IP20 (DIN Rail / Panel Cabinet Installation)
Explosion-proof Grade Standard Intrinsic Safety Design, Suitable for Explosion-proof Zone Class I Div.2 of Power Station
Four. Application Scenarios
Main Scene: Remote Signal Acquisition Station for Heavy-duty Gas Turbines Mark VIe Systems such as GE 9FA/6FA/7HA, Combined with RS-FS-9001 Flame Sensor for Flame Outage Protection Interlock
Large-scale Waste Heat Boilers, Combined Cycle Power Plants, Petrochemical Heating Furnace Control Systems
Remote IO Expansion for Distributed Factory Production Lines, Pump Stations, Compressor Groups
Renovation of Old Units to replace Old Models with Remote Controllers (Replacing the Early IS200 Series Substations)
| RS PART NUMBER | DESCRIPTION |
|---|---|
| RS-FS-9001 | FLAME SENSOR (UV) – NA CLASS I DIV 2, ATEX ZONE 2 |
| RS-FS-9004 | FLAME SENSOR (UV) – NA CLASS I DIV 1, ATEX ZONE 1 |
| RS-FS-9006-MFR | FLAME SENSOR (UV) – AERODERIVATIVE (AS9100) |
| RS-FS-9009-03 | FTD 325 – CLASS I DIV 2, ATEX ZONE 2, NO COOLING REQUIRED, MAX TEMP 325°C |
| RS-FS-9010-03 | FTD 325 – CLASS I DIV 1, ATEX ZONE 1, NO COOLING REQUIRED, MAX TEMP 325°C |
| RS-FS-9009-03-25x | FTD 325 ILG – NO COOLING REQUIRED, MAX TEMP 325°C, INCREASED LOW GAIN FOR LOW INTENSITY LIGHT, CLASS I DIV 2, ATEX ZONE 2 |
| RS-FS-9010-03-25x | FTD 325 ILG – NO COOLING REQUIRED, MAX TEMP 325°C, INCREASED LOW GAIN FOR LOW INTENSITY LIGHT, CLASS I DIV 1, ATEX ZONE 1 |
| RS-FS-9100 | FLAME TRACKER LITE FOR INDUSTRIAL APPLICATIONS |
| RS-FS-9100-RELAY | RELAY, 1CH, D5254S |
| RS-FS-9101 | COIL COOLING WATER (GEPS #353B3490G001) |
| RS-FSM-1002-002 | FLAME SENSOR MODULE, MKV |
| SP-566 | COIL COOLING WATER (GEPS #353B3490G001) |
| RS-E2-0266G091 | KIT: (4) RS-FS-9009-03 / (4) RS-E2-0285P004 / MISC. HARDWARE |
| RS-E2-0266G092 | KIT: (4) RS-FS-9009-03 / (4) RS-E2-0285P004 / (1) RS-FSM-1002-002 / HARDWARE |
| RS-E2-0266G093 | KIT: RS-FS-9009-03 MOUNTING HARDWARE |
| RS-E2-0266G094 | KIT: (1) RS-FS-9100 / (1) RS-E2-0285P021 |
| RS-E2-0266G096 | KIT: (1) RS-FS-9100 / (1) RS-E2-0285P021 / (1) CASE / (1) RS STICKER (2) RS-FS-9009-03 / (2) RS-E2-0285P004 / (1) RS-FSM-1002-002 / |
| RS-E2-0266G097 | KIT: (1) RS-E1-0039-003 / HARDWARE |
| RS-E2-0266G098 | KIT: (2) RS-FS-9009-03 / (2) RS-E2-0285P004 / (1) RS-E1-0039-003 / HARDWARE |
| RS-E2-0266G099 | KIT: (8) RS-FS-9009-03 / (8) RS-E2-0285P004 / (2) RS-FSM-1002-002 / HARDWARE |
| RS-E2-0266G100 | KIT: (8) RS-FS-9009-03 / (8) RS-E2-0285P004 / HARDWARE |
| RS-E2-0285P001 | FLAME SENSOR CABLE: 60FT LONG / RIGHT ANGLE CONNECTOR |
| RS-E2-0285P004 | FLAME SENSOR CABLE: 120FT LONG / RIGHT ANGLE CONNECTOR |
| RS-E2-0285P011 | FLAME SENSOR CABLE: 60FT LONG / STRAIGHT CONNECTOR |
| RS-E2-0285P012 | FLAME SENSOR CABLE: 120FT LONG / STRAIGHT CONNECTOR |
| RS-E2-0285P021 | FLAME SENSOR CABLE: 15FT LONG / RIGHT ANGLE CONNECTOR |
Reuter-Stokes Cross Reference Matrix
| RS PART NUMBER | GE PART NUMBER | REPLACES PART NUMBER | DESCRIPTION |
|---|---|---|---|
| RS-FS-9001 | 362A1052P404 | 362A1052P001 362A1052P003 362A1052P004 362A1052P104 362A1052P203 362A1052P243 362A1052P303 362A1052P304 184X0254M029 RRO00148 | FLAME SENSOR (UV) |
| RS-FS-9004 | 362A1052P105 362A1052P406 362A1052P407 | 362A1052P105 362A1052P106 362A1052P107 362A1052P306 362A1052P307 121T9685P0010 184X0254M123 RRO00149 | FLAME SENSOR (UV) |
| RS-FS-9006-MFR | 362A1379P001 L44819P01 | 8TP10LMX J04937 RS-FS-9006 | FLAME SENSOR (UV) – AERODERIVATIVE |
| RS-FS-9009-03 | 124T5712P0001 | RS-FS-9009-01 RRO00345 | FTD 325 |
| RS-FS-9010-03 | 124T5712P0001 | RS-FS-9009-02 RRO00345 | FTD 325 |
| RS-FS-9009-03-25x | 302T1201P0001 | RS-FS-9009-03 | FTD 325 ILG, ZONE 2 |
| RS-FS-9010-03-25x | 302T1201P0002 | RS-FS-9010-03 | FTD 325 ILG, ZONE 1 |
| SP-566 | 353B3490G001 | 362A1053P031 | COIL COOLING WATER |
| RS-E2-0285P001 | 362A1053P031 | 362A1053P036 | CABLE: 60FT / RIGHT ANGLE |
| RS-E2-0285P004 | 362A1053P036 | RS-E2-0285P013 | CABLE: 120FT / RIGHT ANGLE |
| RS-E2-0285P011 | 362A3342P002 | 362A3342P002 | CABLE: 60FT / STRAIGHT |
| RS-E2-0285P012 | RS-E2-0285P013 | 124T5712P0001 | CABLE: 120FT / STRAIGHT |
| RS-E2-0285P021 | RS-E2-0285P011 | RS-E2-0285P011 | CABLE: 15FT / RIGHT ANGLE |