GE Multilin 139-V-TC-FLC 139 Series Three-Phase Motor Integrated Protection Relay

Brand/Manufacturer:GE Multilin 

Order Number: 139-V-TC-FLC 139

Country of Origin: USA

Condition: Original Brand

Lead Time: Available in stock

Payment Term: 100% TT In Advance


Send Inquiry
Power Duke Automation Equipment Co., Ltd.
Sales Manager: Anne
WeChat: +86 19336875129
Email: Anne@yuanmiaoautomation.com
We can offer you the best price!
Image 2
Image 2

Products Description

The GE Multilin 139 Series Motor Protection Relays were formerly sold under Multilin which was a division of Derlan Manufacturing. The function of these relays is to monitor and protect 3 phase AC Motors.


139-NSF-V-TC Technical Specifications

ManufacturerGeneral Electric Multilin (GE)
Manufacturing LocationMarkham, Ontario, Canada
Load Control % CR Amps ResponseAverage of 3 Phase RMS Values
Mounting OrientationVertical Mount
Operating Temperature Range-10 to 60°C
Output OptionThermal Capacity Metering
Overload Rapid Trip150/200/250/300
Power Supply Voltage120/240 VAC
Control Power Burden.1 VA
Frequency Range50-60 Hz

About the 139-NSF-V-TC

Denoted by the TC characters at the end of the 139-NSF-V-TC relay number the output on this model is a thermal capacity meter. This output type helps determine when the relay is close to tripping due to the various operating conditions when the full load of the relay is either being used in a conveyor or grinding system. This meter type will indicate the approximate memory that has been charged as it corresponds to the heat buildup of the motor. There is a specific feature that will indicate that the relay is about to trip, this indicator is the meter approaching one hundred percent capacity. If a trip does take place the thermal capacity meter will indicate how much charge is left within the memory, and the amount of charge left will indicate an estimate of the lockout time remaining on the relay. 

Relay 139-NSF-V-TC can be used in a variety of applications which includes the protection of the mechanics and personal safety of the pumps of the undercurrent features which can detect a closed discharge valve or potential loss of suction. 

There are several relay testing types available on this model which includes start timer, unbalance, ground fault, and commissioning relay tests. Of course, there are different ways to test each of these features on the 139-NSF-V-TC model. To test the ground fault a single phase must be connected through the window of the current transformer and then slowly increase the current of the test set until the relay trips; please note that the ground fault light will be on when tripped. The current should be equal to the setting value of +0, -25% which will cause the ground fault to trip. If the alarm is enabled the auxiliary relay will activate at a current half of the chosen value. 

Frequently Asked Questions about 139-NSF-V-TC

What order specifications are included with a 139-NSF-V-TC Multilin GE motor protection relay?
The 139-NSF-V-TC contains the additional TC option that is not automatically included in the base 139 Multilin relay. In order to connect the meter to the relay a 0-1 mA output is provided to to drive the thermal capacity meter from terminals one and two. The accuracy of this TC option is not affected by lead length.
What is the function of an unbalance control for a 139-NSF-V-TC Multilin GE motor protection relay?
If there is an unbalance situation in the plant, this can sometimes cause an unbalance in the phase three motor currents. This can result in a loose connection and a rapidly rotatig field which leads to deleterious heat generation with in the rotary. This unbalance control can aid in the prevention of the consequences from such an unstable situation that can have an unpredictable effect on motor. 
What is a start timer used for in a 139-NSF-V-TC Multilin GE motor protection relay?
The start timer is a feature of the 139-NSF-V-TC that provides the protection benefit against a locked rotor situation, a situation with multiple starts, or with excessive loading during motor start-up. Protection in each of these situations helps minimize excessive load current during these prolonged start situations. 